Siemens Simatic S7 Driver

The driver is designed to enable direct communication between Siemens Simatic S7 controllers and Tridium Niagara-powered devices. It provides an efficient solution for industrial systems monitoring, facilitates seamless integration of multiple protocols and allows convenient makeover of front-end software.

PRICE: $1080 - $5269

CONTACT SELLER
VersionsPrice 
Siemens Simatic S7 Driver-JACE-250$2,294.00 
Siemens Simatic S7 Driver-JACE-1000$3,882.00 
Siemens Simatic S7 Driver-JACE-Unlimited$5,269.00 
Siemens Simatic S7 Driver-Supervisor-+ extra 500$1,080.00 
Siemens Simatic S7 Driver-Supervisor-500$3,644.00 

Details

Overview

The driver implements Ethernet S7comm (S7 Communication) - Siemens proprietary protocol that runs between programmable logic controllers (PLCs). It is used for PLC programming, exchanging data between PLCs, accessing PLC data from SCADA (supervisory control and data acquisition) systems and diagnostic purposes.

The protocol is also used on top of other physical/network layers, like RS-485 with MPI (Multi-Point-Interface) or Profibus. However, Ethernet has several advantages against Profibus/Mpi:

  • It’s faster, CP 1543-1 (for the newborn S71500) has a bandwidth of 1000 Mbps
  • It’s simpler to troubleshoot, in 50% of cases a “ping” is good enough to solve your problems
  • It’s cheaper, you don’t need special adapter to communicate

Key features

  • Works with Siemens S7 Ethernet PLCs
  • Enables input/output/timer/counter read and write
  • Enables DB (Data Block) read and write
  • Provides PLC status
  • Allows to START/STOP PLC
  • Supports time sync

Software Version

Niagara-powered device with software N4.1 or later, including JACE, Supervisor or their OEM versions

Licensing Management

Jace: 250 points / 1000 points / unlimited points | Supervisor: 500 points + any number of extra 500 points

Requirements

Supported CPU models and Features

Functions CPUs            
  300 400 WinAC 1200 1500 LOGO S7200
DB Read/Write X X X X1 X1 X2 X2
EB Read/Write X X X X X X2 X2
AB Read/Write X X X X X X2 X2
MK Read/Write X X X X X X2 X2
TM Read/Write X X X - - - -
CT Read/Write X X X - - - -
Get/Set PLC Date and Time 3        X X X - - - -
Get PLC statuses X X X - - - -
Read SZL 3 X X X - - - -
Get AG Block Info 3 X X X - - - -
DB Get 3 X X X - - - -
Control Run/Stop X X X - - - -
Security Function 3 X X X - - - -
  1. Optimized block access must be disabled
  2. The entire memory is mapped in the (V) Area accessible as DB 1 from the outside
  3. Function is in testing stage