Esser Driver

The Tridium Niagara driver allows to connect to Esser Fire Panel via Serial Esser Interface (SEI) module. This way the Esser Fire Alarm System could be upgraded with Niagara graphics or integrated with a variety of BMS protocols supported by Niagara.

PRICE: $1130.00 - $5007.00

CONTACT SELLER
Image

Details

Overview

The Tridium Niagara driver allows to connect to Esser Fire Panel via Serial Esser Interface (SEI) module. This way the Esser Fire Alarm System could be upgraded with Niagara graphics or integrated with a variety of BMS protocols supported by Niagara.

Structure of the Esser network and devices is created automatically without complex engineering by importing files from Esser configuration tool. All the devices retain their names, types and unit facets, which greatly simplifies the integration process.

Key features

  • Communicates via Serial Esser Interface (SEI) module and RS-232
  • Supports both Esser panel series – IQ8 and FlexES
  • Discovery process from imported configuration file
  • Supports multiple Esser panels
  • Connection with JACE or Supervisor
  • Includes pallet of graphical widgets
  • Enum switcher, Telegram history and more supporting tools for smooth integration

Supported devices

  • Fire Panel: FlexES FX series
  • Fire Panel: IQ8Control series
  • Serial Essernet Interface (SEI) version 2.03R011 and later
VersionsPrice
EsserDriver-Unlimited$5,007.00
EsserDriver-250$1,130.00

Frequently asked questions

Question: How can I send a command to the panel or detector?

Discover an appropriate device or add it manually to the database. Right click on it and from context menu select actions –> choose the available command.

Question: I cannot send command to the Panel. It doesn’t work!

Check whether you have set the correct Panel ID.

Question: Can I read the current time setting from Panel and change it?

Use the context menu on the Essernet Network. If the SEI has address 1, it will resend the time to all connected panels.

Question: Palette has no components or showing white space or content of previously selected palette!

Make sure, you have Essernet module in your local modules directory.

Question: LED diode on SEI is still red and connection is not working!

Check the SEI wiring and communicator setup. Then restart your station.

Software Version

Niagara Supervisor with software v3.8 (AX), v4.10 (N4) or later.

Licensing Management

Supervisor 250/unlimited points

Requirements

  • Niagara Supervisor and 3rd party system cyclically exporting data in CSV file. 
  • It is assumed that the user is trained in the use of Niagara 4.
  • You must read the End User License Agreement before using this software.